MCVT405 CT/PT Analyzer
1) Standar tes: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2) Sumber daya: AC220V ± 10%, 50/60Hz ± 10%
3) Tegangan / Output Saiki: 0.1 ~ 180V (AC) / 0.001 ~ 5A (RMS)
5) Daya output: 500VA
6) pangukuran voltase dhengkul maksimum: 45KV
7) Pangukuran saiki
Range: 0 ~ 10A (otomatis ngganti sawetara ing 0.1/0.4/2/10A)
Kasalahan: <± 0,1% + 0,01% FS
8) Pengukuran tegangan
Range: 0 ~ 200V (otomatis ngganti kisaran ing 1V/10V/70V/200V)
Kasalahan: < ± 0,1% + 0,01% FS
9) Nguripake pangukuran rasio & kesalahan
Range: 1~35000
1~5000 (kasalahan<0,05%) & 5000~35000 (salah<0,1%)
10) Kesalahan pangukuran fase: ± 2min & resolusi: 0.01min
11) Pengukuran resistance winding
Range: 0 ~ 8kΩ (otomatis ngganti kisaran ing 2ohm/20ohm/80ohm/800ohm/8kohm)
Kasalahan: <0.2%RDG+0.02%FS
Résolusi maksimum: 0.1mΩ
12) pangukuran suhu:-50 ~ 100 derajat Celsius;kesalahan <3 derajat Celsius
13) CT Beban sekunder
Range: 0~160ohm (otomatis ngganti kisaran ing 2ohm/20ohm/80ohm/160ohm)
Kasalahan: <0.2%RDG+0.02%FS
Resolusi maksimum: 0.001 ohm
14) PT Beban Sekunder
Range: 0~80kohm (otomatis ngganti kisaran ing 800ohm/8kohm/80kohm)
Kasalahan: <0.2%RDG+0.02%FS
Resolusi maksimum: 0.1 ohm
15) Pengukuran rasio PT & kesalahan
Range: 1~35000
1~10000 (kasalahan<0,1%) & 10000~35000 (salah<0,2%)
16) Pangukuran kesalahan rasio PT: Kesalahan tipikal <0,05%, Kesalahan Maksimum <0,1%
17) Pengukuran sudut fase PT: kesalahan maksimal < 3 menit
18) Nggawe evaluasi asil tes miturut standar sing dipilih
19) Nggawe laporan tembung kanggo asil tes
20) Nggawe laporan tembung sapisan kanggo cathetan test multi-kelompok ing PC
21) Ngitung kesalahan rasio lan kesalahan sudut fase ing beban sing dirating lan beban kerja ing tes siji wektu
22) Mbandhingake kurva eksitasi karo kurva eksitasi sing disimpen ing jendela sing padha
23) Kapasitas memori: > 1000 asil tes kelompok
24) Kondisi kerja: suhu: -10 ℃ ~ 50 ℃;lembab: ≤90%
25) Ukuran: 485mm × 356mm × 183mm
26) Bobot: <15kg